Skip to main content

ORIGINAL RESEARCH article

Front. Surg., 14 September 2022
Sec. Orthopedic Surgery
Volume 9 - 2022 | https://doi.org/10.3389/fsurg.2022.917853

The high resistance loop (H-loop) technique used for all-inside arthroscopic knotless suprapectoral biceps tenodesis: A case series

Min Zhou Chuanhai Zhou Dedong Cui Yi Long Jiang Guo Zhenze Zheng Ke Meng Jinming Zhang Jingyi Hou* Rui Yang*
  • Department of Orthopaedic Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China

Introduction: Suprapectoral tenodesis is a common technique for the treatment of long head biceps tendon lesions. However, so far, there is no gold standard treatment in all-inside arthroscopy. The purpose of the present study was to introduce and evaluate the functional outcomes of an innovative, all-inside arthroscopic high resistance loop (H-loop, high resistance to tissue cutout and 360° grasping of the tendon) technique for long head of biceps (LHB) tenodesis.

Method: From September 2020 to March 2022, a series of cases of 32 consecutive patients (28 rotator cuff tear with LHBT pathology and 4 superior labrum anterior-posterior (SLAP) tears which including 2 type II and 2 type IV) who received LHB tenodesis using all-inside arthroscopic high resistance loop technique were included in this study. The American Shoulder and Elbow Surgeon Score (ASES), Visual Analog Scale (VAS), Simple Shoulder Test Score (SST), Constant–Murley scores, and University of California at Los Angeles Scoring System (UCLA) were used to evaluate the clinical outcomes of patients in preoperative and final follow-up. Meanwhile, postoperative complications were also observed.

Result: 32 patients (14 women and 18 men, average age was 55.7 years) underwent all-inside arthroscopic knotless suprapectoral biceps tenodesis using the H-Loop stitch technique. The mean time of follow-up was 16.2 ± 2.6 months. The ASES, VAS, Constant–Murley, SST, and UCLA scores improved from 51.5 ± 15.8, 5.5 ± 1.6, 57.8 ± 14.7, 5.0 ± 2.8, and 16.1 ± 3.8 preoperatively, to 89.1 ± 7.5, 1.0 ± 0.8, 87.3 ± 5.5, 10.4 ± 1.5, and 31.3 ± 2.6 in the last follow-up, respectively (p < 0.001). During the follow-up, no patients in this study experienced postoperative complications such as infection of the wound, injury of nerves, and hardware failure; no patients required revision after their operation. In addition, none of the patients had cramping or a “Popeye” deformity during follow-up.

Conclusion: This article presents an innovative, all-arthroscopic H-loop technique for LHB tenodesis. This technique for LHB tenodesis showed favorable functional and cosmetic outcomes, as well as high satisfaction rates. Due to its simplicity of operation and satisfactory preliminary clinical outcomes, H-loop technique is perhaps another option to choose in all-inside arthroscopic LHB tenodesis.

Introduction

Lesions of the long head of the biceps tendon (LHBT) usually lead to pain of the shoulder and disability, and more than 60% of patients have a rotator cuff tear (1). Tenotomy and tenodesis are effective but controversial techniques for the treatment of LHBT lesions; however, there was no difference in functional results between tenotomy and tenodesis in recent studies (2).

LHBT tenotomy is technically easier to perform and is associated with early amelioration of post-operative pain, but the incidence of cosmetic deformities is higher (25%–62%) (35). However, in young or elderly patients with higher requirements, tenodesis is suggested to reduce the occurrence of cramping, “Popeye” deformity, and weakness in the biceps brachii (6, 7).

To overcome this problem, several LHBT fixation techniques have been described, including open and arthroscopic techniques, which provided satisfactory results without clinically significant differences (8, 9). A study performed by Gombera et al. compared arthroscopic with open LHB tenodesis (10). The results showed similar clinical outcomes between the arthroscopic suprapectoral tenodesis and open subrapectoral tenodesis groups. However, they announced that open subpectoral tenodesis may be associated with an increased risk of complications because of its requirement to expose more tissue. For open subrapectoral tenodesis, some complications have been reported, such as neurovascular injury (11, 12), fractures (1316), and deep infection (17, 18); but the complications above can be mitigated by adopting an arthroscopic approach (1921).

Numerous types of tenodesis techniques can be used to treat LHBT pathology, such as suture anchor, interference screw, and cortical button (2224). Biomechanics studies have evaluated these different tenodesis techniques and showed slight differences; but there was no difference in clinical outcomes (6, 25, 26). Therefore, using a relatively simple and safe fixation method is the best choice for tenodesis.

Regarding tenodesis with suture anchor via arthroscopy, the Lasso-Loop stitch was commonly used (2731).This technique provided strong tissue grasping ability, which was equivalent to interference screws (32). However, compared to the Krakow Stitch, Lasso-Loop stitch had a critical defect where the uneven load distribution of sutured tendon might lead to poor tendon fixation strength (33).

To solve these specific problems, a new Loop stich, high resistance loop (H-Loop) (invented by Jingyi Hou), was developed to provide 360° grasping of the tendon and to correct unevenness of sutured tendon load distribution. In this study, the circumferential high resistance loop grasping LHBT was introduced. The purposes of this research were: (i) to present the H-Loop stitch technique in arthroscopic LHB tenodesis; (ii) to assess the preliminary outcomes in patients with LHB tenodesis using the H-Loop stitch technique.

Materials and methods

Patient selection

The study was approved by the Ethics Committee of Sun Yat-sen Memorial Hospital of Sun Yat-sen University (SYSEC-KY-KS-2021-303), and abided by the Declaration of Helsinki and the Guidelines for Good Clinical Practice. A retrospective case series data on patients between September 2020 and March 2022 who have undergone all-inside arthroscopic knotless suprapectoral biceps tenodesis with H-Loop stitch by the senior author (R.Y.) was prospectively and consecutively collected.

The inclusive criteria included: (i) patients over 18 years of age who were diagnosed with LHBT pathologies; (ii) all arthroscopic biceps tenodesis with H-Loop stitch technique performed together with arthroscopic repair of a rotator cuff tear or superior labrum anterior-posterior (SLAP) tears; (iii) magnetic resonance imaging demonstrating LHBT pathologies that did not improve with conservative treatment after 6 months; (iv) shoulder functions were recorded and the pre- and post-operative last follow-up were compared using the American Shoulder and Elbow Surgeon Score (ASES) (34), Visual Analog Scale (VAS), Simple Shoulder Test Score (SST), Constant–Murley scores (35), and University of California at Los Angeles Scoring System(UCLA) (36). Exclusion criteria included: revision surgery after rotator cuff repair, shoulder osteoarthritis, adhesive capsulitis, and individuals with marked deformity and/or neuromuscular diseases.

According to the inclusion and exclusion criteria, a total of 32 consecutive patients (14 women, 18 men) who were diagnosed with LHBT lesions (28 rotator cuff tear with LHBT pathology and 4 superior labrum anterior-posterior (SLAP) tears which including 2 type II and 2 type IV) and were surgically treated with the all-inside arthroscopic knotless suprapectoral biceps tenodesis with H-Loop stitch were enrolled in this study. Before the operation, all patients received extensive shoulder examination, including physical, x-ray, and MRI examination, and were diagnosed with LHBT lesion with or without other concomitant diseases of the shoulder.

Surgical technique

Anesthesia and patient positioning

After general anesthesia, the patient was placed in a lateral decubitus position on the operation table. Then, the operative shoulder was placed at 20° forward flexion and 35°–45° abduction. Continuous traction was applied through the ipsilateral upper extremity to gain a larger operative space in the glenohumeral joint.

Diagnostic arthroscopy

The standard routine portal was established in turn: posterior, anterior, and anterolateral portal. The glenohumeral joint and long head of the biceps tendon was examined thoroughly through the posterior portal. To clarify the pathological changes of the intertubercular groove part of the LHBT, the LHB needs to be pulled toward the intra-articular area using probes from the anterior approach. Hence, an anterior approach was established under arthroscopic surveillance. Additionally, a lateral portal was established by spinal needle for rotator cuff repair (Figure 1).

FIGURE 1
www.frontiersin.org

Figure 1. The standard anterior portal, lateral portal, posterior portal, anterosuperior portal and, portal of Wilmington had been marked.

The H-loop stitch technique for long head of the biceps tendon

Once the LHBT tenodesis was determined, a FiberWire suture (2#, Arthrex, Naples, FL) was folded in half and inserted into the capsule with the suture grasper from the anterior portal. The suture was first released at the superior aspect of the tendon near the insertion point. One free end of the suture was held on to outside the arthroscope and the suture was grasped from the inferior aspect of the tendon in the arthroscope, while another end of the suture was pulled outside the arthroscope to construct a loop hitching around the LHBT. A SutureLasso SD 90° (Arthrex, Naples, FL), the suture shuttle device, was pierced through the midportion of the LHBT just distal to the loop through the anterior portal to advance a 0# PDS II (polydioxanone suture) (Ethicon Inc; Johnson / Johnson, Somerville, NJ) as a guiding suture. Subsequently, the SutureLasso was retrieved, and the end of the PDS suture in the capsule was grasped out through the posterior portal. A tight overhand knot was tied on the two ends of the FiberWire suture with the PDS suture. Finally, the PDS suture was pulled out from the posterior portal, helping the two suture ends shuttle the tendon. Then, a novel, self-locking, high-resistant loop configuration was constructed after removing the PDS suture (Figures 2A–E).

FIGURE 2
www.frontiersin.org

Figure 2. Demonstration of the high resistance loop (H-Loop) stich technique arthroscopic surgical in shoulder as viewed from the posterior portal with the patient in the lateral decubitus position using a 30° scope. (A) a 2# Fiber Wire suture (Arthrex, Naples, FL) was folded in half and inserted into glenohumeral joint and construct a loop hitching around the LHBT; (B) A Suture Lasso is pierced through the midportion of the LHBT just distal of the loop to advance a 0# PDS II Suture, as a guiding suture. (C) The two ends of Fiberwire suture were brought into midportion of the LHBT just distal of the loop with PDS suture; (D) A novel, self-locking, high-resistant rip-stop loop configuration was constructed; (E) The origin of LHBT was detached with a curved arthroscopic scissor. (F) The two free ends of the suture were pressed into the guide hole with a push lock anchor suture (Arthrex, Naples, FL) at the intertubercular groove.

Long head biceps tenodesis

A punch forcep was inserted into the articular cavity through the anterior portal to detach the LHBT at the insertion site on the superior labral junction. The arthroscope was subsequently shifted to the subacromial space. The transverse ligament was completely cut and the LHBT was thoroughly exposed in the bicipital groove with radiofrequency ablation through the anterolateral portal. The tendon was provoked with the probe to further expose the bicipital groove and thorough debridement was performed with an arthroscopic burr to refresh the intended anchor site. A pilot hole was drilled via the bicipital groove approach to the capsule border perpendicularly with a punch for the 4.75 mm SwiveLock C Anchor (Arthrex, Naples, FL). Two free ends of the suture were loaded into the eyelet of the anchor. Finally, the anchor was placed into the pilot hole, and the tail sutures under the anchor were cut off (Figure 2F).

Rehabilitation

The arm was placed in 30° abduction with an abduction brace for 6 weeks after operation. At this stage, patients were allowed to perform gentle pendulum exercises and elbow/wrist range of motion exercises under the conduct of a physical therapist. After 6 weeks, active exercises of the shoulder and biceps were initiated. 12 weeks after the operation, biceps strengthening programs were started.

Clinical outcomes measure

The clinical results of preoperative and postoperative final follow-up were evaluated by the following scales: ASES, VAS, Constant–Murley, SST, and UCLA score. And the cramps, “Popeye” deformity, tenderness of the bicipital groove, pain during the performance of the Speed test were also evaluated. In the final follow-up, the satisfaction of this technique had been evaluated.

Statistical analysis

SPSS 20.0 (IBM, Armonk, USA) was used for statistical analysis. The ASES, VAS, Constant–Murley, SST, and UCLA scores between preoperative and final follow-up were compared with Wilcoxon signed-rank test for non-parametric data sets, where a P value of <0.05 was considered statistically significant. The categorical variables were measured by proportion.

Results

General outcomes

The age of patients ranged from 34 to 68 years, with a mean of 55.7 years. All cases have been followed up recently. The mean follow-up was 17 months (range, 12–20 months). In this cohort of patients, the pathology of LHBT was defined during arthroscopic surgery, and the indications for biceps tenodesis included partial tear of the LHB, symptomatic LHB tendinitis, chronic LHB tendinopathy, type 2 and type 4 SLAP tears, and subluxated or dislocated LHB with associated rotator cuff tear. Of the 32 patients, 30 (93.8%) had at least 1 additional intervention during biceps tenodesis.

Functional outcomes

ASES score

The clinical scores of the ASES showed that the mean preoperative score was 51.5 (SD = 15.8) and the mean score during the final postoperative follow-up was 89.06 (SD = 7.48), with a statistically significant difference (p < 0.001).

VAS score

The clinical scores of the VAS scale showed that the mean preoperative pain score was 5.5 (SD = 1.6) and the mean pain score during the final postoperative follow-up was 0.97 (SD = 0.82), with a statistically significant difference (p < 0.001).

Constant–murley score

The clinical scores of Constant–Murley showed that the mean preoperative score was 57.8 (SD = 14.7) and the mean pain score during the final postoperative follow-up was 87.3 (SD = 5.5), with a statistically significant difference (p < 0.001).

SST score

The clinical scores of the SST showed that the mean preoperative score was 5.0 (SD = 2.8) and the mean pain score during the final postoperative follow-up was 10.4 (SD = 1.5), with a statistically significant difference (p < 0.001).

UCLA score

The clinical scores of the UCLA showed that the mean preoperative score was 16.06 (SD = 3.8) and the mean pain score during the final postoperative follow-up was 31.3 (SD = 2.6), with a statistically significant difference (p < 0.001).

The procedure has high patient satisfaction; 62.5% (12/32) of patients classified the clinical outcome as excellent and 37.5% (12/32,) as good (residual gentle tenderness in intertubercular/bicipital groove). At the final follow-up after surgery, all patients returned to their daily lives without limitations.

Complications

During the follow-up, no patients in this study experienced postoperative complications such as infection of the wound, injury of nerves, and hardware failure; no patients required revision after their operation. In addition, none of the patients had cramping or a “Popeye” deformity during the final follow-up after surgery.

Discussion

The present study was designed to introduce the all-inside arthroscopic knotless suprapectoral biceps tenodesis with H-Loop stitch and to access the preliminary outcomes in patients with LHB tenodesis using the H-Loop stitch technique. The principle finding of the present study presented good clinical results and acquired a high rate of patient satisfaction. The functional scores and pain of patients demonstrated significant improvement. No patients in this study experienced nerve damage and re-operation postoperatively. All-inside arthroscopic knotless suprapectoral biceps tenodesis with H-Loop stitch is a treatment option for LHBT disorders.

Optimal tenodesis remains a contentious issue, with current tenodesis hardware options including a wide range of implants such as interference screws, cortical buttons, and suture anchors (2224). Due to the high biomechanical stability and good clinical outcomes, the interference screw technique has been widely used in LHB tenodesis (18, 37). However, some serious adverse events related to interference screw LHB tenodesis have also been reported successively, including humeral shaft fractures, tendon injuries within bone tunnels, and local reactions for bioabsorbable screws (38, 39). To further investigate the complications of the interference screw bone tunnel tenodesis, relevant biomechanical studies have been recently performed. The results of this study showed similar ultimate failure loads and stiffness of all-suture anchor and interference screw constructs. However, in the torsion test, implant-related fractures occurred in only 29% of the suture anchor tenodesis structures versus 170% of the interference screw tenodesis structures (25). In clinical practice, the interference screw bone tunnel tenodesis technique has been confirmed to have a higher incidence rate of postoperative cosmetic deformities and revision surgery as compared with the all-suture anchor bone surface tenodesis technique (26). Therefore, the suture anchor bone surface tenodesis technique was proposed as a reasonable option to reduce these risks. The current preliminary clinical results may support these findings, because neither humeral shaft fractures nor cosmetic deformities were observed at the final follow-up.

The suture anchor fixation technique for tenodesis is a simple and relatively safe fixation method and is widely accepted by surgeons. Lafosse first described the “Lasso-loop” technique to tenodesis in all-arthroscopic surgery (27). Additionally, other investigators have found “Lasso-loop” LHB tenodesis with suture anchor achieved more stronger and securer than the LHB tenodesis with interference screws (32). However, other biomechanical testing has demonstrated that the “Lasso-loop” technique holds only a portion of the tendon, which results in an unbalanced suture tendon load distribution, and does not avoid failure of tendon fixation due to the cutting effect of sutures on the tendon (33). To address these specific problems, Sebastian et al. introduced the Lasso Loop 360 technique to provide secure fixation and improved biomechanical properties. Compared with the Lasso-loop technology, the maximum failure load, displacement, and stiffness of Lasso Loop 360 have been improved (40). However, this technique did not solve the problem of tendon cutting by suture; meanwhile, the results of this technique were only ideal for experimental conditions and has not been clinically used and confirmed.

All-inside arthroscopic knotless suprapectoral biceps on-lay tenodesis with H-Loop stitch, which is a novel, total-grasp, self-locking, and high resistance stitch technique has obtained satisfactory clinical results in this case series. The H-loop stitch technique emphasizes the grasping of the whole biceps longus tendon, and not only demonstrates strong grip organization but also acts as a self-tightening force under stressful conditions (41). In addition, this suture loop opposes each other with the free limb of the suture, which can function as a rip-stop to prevent cutting of the tendon at the suture interface (42). The advantages of this technique are simple operation, excellent visualization, and easy to be taught and repeated under arthroscopy. At the same time, it is a cost-effective technology, because: (1) It is a simple and time-consuming technology, which saves operation time; (2) The two suture limbs can be pressed under the lateral row handling the rotator cuff without additional implants, which also reduces cost by eliminating the need for additional implants for tenodesis; (3) There is no need for an extra instrument, which can be completed with a simple lasso. In addition, this technique could be completed under arthroscopy, does not require additional separate incisions and may reduce surgical morbidity. A schematic of the steps of H-loop stitch is summarized in Figure 3. Technology-related tips and tricks are detailed in Table 1. Complete advantages and disadvantages are listed in Table 2.

FIGURE 3
www.frontiersin.org

Figure 3. Illustrations summarizing the steps required to create H-LOOP tenodesis of LHB.

TABLE 1
www.frontiersin.org

Table 1. Technical pearls and pitfalls of H-loop tenodesis of LHB.

TABLE 2
www.frontiersin.org

Table 2. Advantages and disadvantages of H-loop tenodesis of LHB.

The following limitations of our study must be considered. First, this tenodesis technique has potential limitations similar to those of other all-arthroscopic tenodesis techniques. This is because this technique is simply performed to fix the LHBT at the proximal part of the bicipital groove. Because thorough debridement of the intertubercular groove is not performed during the procedure, it is possible that the remnant of lesional tissue leads to residual anterior shoulder pain25. Secondly, the small sample size and short follow-up duration might not be enough to obtain accurate outcomes. Hence, a large sample size and longer follow-up durations are needed to obtain more precise conclusions. Thirdly, the study is short of an appropriate control group, where a randomized design comparing the H-loop tenodesis technique with the conventional tenodesis technique is required. Fourthly, patients underwent rotator cuff repair and LHB tenodesis, which confounded our results. Fifthly, data of biomechanics are lacking, and the mechanical superiority of this technology needs to be further confirmed by biomechanics in the future.

Conclusion

This article presents an innovative, all-arthroscopic H-loop technique for LHB tenodesis. Although the biomechanics of this tendon fixation technique have not been studied, it has shown favorable functional and cosmetic outcomes. Due to its simplicity of operation and satisfactory preliminary clinical outcomes, all-inside arthroscopic knotless suprapectoral biceps tenodesis with H-Loop stitch is another treatment option for LHBT disorders. However, the mechanical superiority of this technology needs to be further confirmed by biomechanics, and long-term clinical outcomes should have to follow to confirm the sustainable success of this promising technique.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

The studies involving human participants were reviewed and approved by Ethics Committee of Sun Yat-sen Memorial Hospital of Sun Yat-sen University. The patients/participants provided their written informed consent to participate in this study.

Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.

Author contributions

MZ and CHZ designed the study and contributed to writing of the draft. DDC and YL contributed to data analysis and solved technical problems in software. JG and JMZ participated in data extraction and analysis assistance. ZZZ and KM contributed to data collection. JYH and RY participated in the design of this research and provided guidance and troubleshooting. All authors agree to be accountable for all aspects of the work. All authors read and approved the final manuscript. All authors contributed to the article and approved the submitted version.

Funding

This work was supported by the National Natural Science Foundation of China (NO. 81972067, 82002342) and the Fundamental Research Funds for the Central Universities, Sun Yat-sen University (NO. 2020004).

Acknowledgments

The authors acknowledge Phei-Er Saw for proofreading this manuscript and polishing the language.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Mardani-Kivi M, Keyhani S, Ebrahim-Zadeh MH, Hashemi-Motlagh K, Saheb-Ekhtiari K. Rotator cuff tear with concomitant long head of biceps tendon (LHBT) degeneration: what is the preferred choice? Open subpectoral versus arthroscopic intraarticular tenodesis. J Orthop Traumatol. (2019) 20(1):26. doi: 10.1186/s10195-019-0531-5

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Vajda M, Szakó L, Hegyi P, Erőss B, Görbe A, Molnár Z, et al. Tenodesis yields better functional results than tenotomy in long head of the biceps tendon operations-a systematic review and meta-analysis. Int Orthop. (2022) 46(5):1037–51. doi: 10.1007/s00264-022-05338-9

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Belay ES, Wittstein JR, Garrigues GE, Lassiter TE, Scribani M, Goldner RD, et al. Biceps tenotomy has earlier pain relief compared to biceps tenodesis: a randomized prospective study. Knee Surg Sports Traumatol Arthrosc. (2019) 27(12):4032–7. doi: 10.1007/s00167-019-05682-1

PubMed Abstract | CrossRef Full Text | Google Scholar

4. Walch G, Edwards TB, Boulahia A, Nové-Josserand L, Neyton L, Szabo I. Arthroscopic tenotomy of the long head of the biceps in the treatment of rotator cuff tears: clinical and radiographic results of 307 cases. J Shoulder Elbow Surg. (2005) 14(3):238–46. doi: 10.1016/j.jse.2004.07.008

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Boileau P, Baqué F, Valerio L, Ahrens P, Chuinard C, Trojani C. Isolated arthroscopic biceps tenotomy or tenodesis improves symptoms in patients with massive irreparable rotator cuff tears. J Bone Joint Surg Am. (2007) 89(4):747–57. doi: 10.2106/00004623-200704000-00008

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Hsu AR, Ghodadra NS, Provencher MT, Lewis PB, Bach BR. Biceps tenotomy versus tenodesis: a review of clinical outcomes and biomechanical results. J Shoulder Elbow Surg. (2011) 20(2):326–32. doi: 10.1016/j.jse.2010.08.019

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Rhee SM, Jeong HY, Ro K, Pancholi S, Rhee YG. Double on-lay fixation using all suture-type anchor for subpectoral biceps tenodesis has favorable functional outcomes and leads to less cosmetic deformities than single on-lay fixation. Knee Surg Sports Traumatol Arthrosc. (2019) 27(12):4005–13. doi: 10.1007/s00167-019-05663-4

PubMed Abstract | CrossRef Full Text | Google Scholar

8. Abraham VT, Tan BH, Kumar VP. Systematic review of biceps tenodesis: arthroscopic versus open. Arthroscopy. (2016) 32(2):365–71. doi: 10.1016/j.arthro.2015.07.028

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Vetoshkin AA, Aghamalyan HH, Gurbannazarov MK. Technique of arthroscopic suprapectoral tenodesis of the long head of the biceps with interference screw. Arthrosc Tech. (2021) 10(4):e1137–41. doi: 10.1016/j.eats.2021.01.008

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Gombera MM, Kahlenberg CA, Nair R, Saltzman MD, Terry MA. All-arthroscopic suprapectoral versus open subpectoral tenodesis of the long head of the biceps brachii. Am J Sports Med. (2015) 43(5):1077–83. doi: 10.1177/0363546515570024

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Ma H, Van Heest A, Glisson C, Patel S. Musculocutaneous nerve entrapment: an unusual complication after biceps tenodesis. Am J Sports Med. (2009) 37(12):2467–9. doi: 10.1177/0363546509337406

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Nho SJ, Reiff SN, Verma NN, Slabaugh MA, Mazzocca AD, Romeo AA. Complications associated with subpectoral biceps tenodesis: low rates of incidence following surgery. J Shoulder Elbow Surg. (2010) 19(5):764–8. doi: 10.1016/j.jse.2010.01.024

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Reiff SN, Nho SJ, Romeo AA. Proximal humerus fracture after keyhole biceps tenodesis. Am J Orthop (Belle Mead NJ). (2010) 39(7):E61–3.20844775

PubMed Abstract | Google Scholar

14. Sears BW, Spencer EE, Getz CL. Humeral fracture following subpectoral biceps tenodesis in 2 active, healthy patients. J Shoulder Elbow Surg. (2011) 20(6):e7–11. doi: 10.1016/j.jse.2011.02.020

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Dein EJ, Huri G, Gordon JC, McFarland EG. A humerus fracture in a baseball pitcher after biceps tenodesis. Am J Sports Med. (2014) 42(4):877–9. doi: 10.1177/0363546513519218

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Huddleston HP, Kurtzman JS, Gedailovich S, Koehler SM, Aibinder WR. The rate and reporting of fracture after biceps tenodesis: a systematic review. J Orthop. (2021) 28:70–85. doi: 10.1016/j.jor.2021.11.014

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Abtahi AM, Granger EK, Tashjian RZ. Complications after subpectoral biceps tenodesis using a dual suture anchor technique. Int J Shoulder Surg. (2014) 8(2):47–50. doi: 10.4103/0973-6042.137527

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Provencher MT, McCormick F, Peebles LA, Beaulieu-Jones BR, Dekker TJ, LeClere LE, et al. Outcomes of primary biceps subpectoral tenodesis in an active population: a prospective evaluation of 101 patients. Arthroscopy. (2019) 35(12):3205–10. doi: 10.1016/j.arthro.2019.06.035

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Oflazoglu K, Menendez ME, Ring D, O'Brien TM, Archibald JD. Axillary artery injury associated with subpectoral biceps tenodesis: a case report. J Shoulder Elbow Surg. (2016) 25(1):e25–8. doi: 10.1016/j.jse.2015.09.021

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Rhee PC, Spinner RJ, Bishop AT, Shin AY. Iatrogenic brachial plexus injuries associated with open subpectoral biceps tenodesis: a report of 4 cases. Am J Sports Med. (2013) 41(9):2048–53. doi: 10.1177/0363546513495646

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Virk MS, Nicholson GP. Complications of proximal biceps tenotomy and tenodesis. Clin Sports Med. (2016) 35(1):181–8. doi: 10.1016/j.csm.2015.08.011

PubMed Abstract | CrossRef Full Text | Google Scholar

22. DeAngelis JP, Chen A, Wexler M, Hertz B, Grimaldi Bournissaint L, Nazarian A, et al. Biomechanical characterization of unicortical button fixation: a novel technique for proximal subpectoral biceps tenodesis. Knee Surg Sports Traumatol Arthrosc. (2015) 23(5):1434–41. doi: 10.1007/s00167-013-2775-6

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Green JM, Getelman MH, Snyder SJ, Burns JP. All-arthroscopic suprapectoral versus open subpectoral tenodesis of the long head of the biceps brachii without the use of interference screws. Arthroscopy. (2017) 33(1):19–25. doi: 10.1016/j.arthro.2016.07.007

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Kennedy NI, Godin JA, Ferrari MB, Sanchez G, Cinque ME, Hussain ZB, et al. Subpectoral biceps tenodesis: interference screw and cortical button fixation. Arthrosc Tech. (2017) 6(4):e1415–e20. doi: 10.1016/j.eats.2017.05.028

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Frank RM, Bernardoni ED, Veera SS, Waterman BR, Griffin JW, Shewman EF, et al. Biomechanical analysis of all-suture suture anchor fixation compared with conventional suture anchors and interference screws for biceps tenodesis. Arthroscopy. (2019) 35(6):1760–8. doi: 10.1016/j.arthro.2019.01.026

PubMed Abstract | CrossRef Full Text | Google Scholar

26. Haidamous G, Noyes MP, Denard PJ. Arthroscopic biceps tenodesis outcomes: a comparison of inlay and onlay techniques. Am J Sports Med. (2020) 48(12):3051–6. doi: 10.1177/0363546520952357

PubMed Abstract | CrossRef Full Text | Google Scholar

27. Lafosse L, Van Raebroeckx A, Brzoska R. A new technique to improve tissue grip: “the lasso-loop stitch”. Arthroscopy. (2006) 22(11):1246. e1-3. doi: 10.1016/j.arthro.2006.05.021

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Uschok S, Herrmann S, Pauly S, Perka C, Greiner S. Combined arthroscopic tenodesis of the long head of biceps and rotator cuff repair in antero-superior cuff tears. Arch Orthop Trauma Surg. (2016) 136(9):1273–9. doi: 10.1007/s00402-016-2498-5

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Hufeland M, Kolem C, Ziskoven C, Kircher J, Krauspe R, Patzer T. The influence of suprapectoral arthroscopic biceps tenodesis for isolated biceps lesions on elbow flexion force and clinical outcomes. Knee Surg Sports Traumatol Arthrosc. (2017) 25(10):3220–8. doi: 10.1007/s00167-015-3846-7

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Schrock JB, Kraeutler MJ, Bravman JT. Comparison of clinical failure rates after 2 techniques of subpectoral mini-open biceps tenodesis: sequence and suture passage technique matter. Orthop J Sports Med. (2017) 5(9):2325967117729356. doi: 10.1177/2325967117729356

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Cabarcas BC, Beletsky A, Liu J, Gowd AK, Manderle BJ, Cohn M, et al. Short-term clinical and return-to-work outcomes after arthroscopic suprapectoral onlay biceps tenodesis with a single suture anchor. Arthrosc Sports Med Rehabil. (2021) 3(4):e1065–e76. doi: 10.1016/j.asmr.2021.03.012

PubMed Abstract | CrossRef Full Text | Google Scholar

32. Patzer T, Rundic JM, Bobrowitsch E, Olender GD, Hurschler C, Schofer MD. Biomechanical comparison of arthroscopically performable techniques for suprapectoral biceps tenodesis. Arthroscopy. (2011) 27(8):1036–47. doi: 10.1016/j.arthro.2011.03.082

PubMed Abstract | CrossRef Full Text | Google Scholar

33. Kaback LA, Gowda AL, Paller D, Green A, Blaine T. Long head biceps tenodesis with a knotless cinch suture anchor: a biomechanical analysis. Arthroscopy. (2015) 31(5):831–5. doi: 10.1016/j.arthro.2014.11.043

PubMed Abstract | CrossRef Full Text | Google Scholar

34. Richards RR, An KN, Bigliani LU, Friedman RJ, Gartsman GM, Gristina AG, et al. A standardized method for the assessment of shoulder function. J Shoulder Elbow Surg. (1994) 3(6):347–52. doi: 10.1016/S1058-2746(09)80019-0

PubMed Abstract | CrossRef Full Text | Google Scholar

35. Scheibel M, Schröder RJ, Chen J, Bartsch M. Arthroscopic soft tissue tenodesis versus bony fixation anchor tenodesis of the long head of the biceps tendon. Am J Sports Med. (2011) 39(5):1046–52. doi: 10.1177/0363546510390777

PubMed Abstract | CrossRef Full Text | Google Scholar

36. Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. (1987) 214:160–4. doi: 10.1097/00003086-198701000-00023

CrossRef Full Text | Google Scholar

37. Griffin JW, Cvetanovich GL, Kim J, Leroux TS, Riboh J, Bach BR, et al. Biceps tenodesis is a viable option for management of proximal biceps injuries in patients less than 25 years of age. Arthroscopy. (2019) 35(4):1036–41. doi: 10.1016/j.arthro.2018.10.151

PubMed Abstract | CrossRef Full Text | Google Scholar

38. Mellano CR, Frank RM, Shin JJ, Jain A, Zuke WA, Mascarenhas R, et al. Subpectoral biceps tenodesis with PEEK interference screw: a biomechanical analysis of humeral fracture risk. Arthroscopy. (2018) 34(3):806–13. doi: 10.1016/j.arthro.2017.09.012

PubMed Abstract | CrossRef Full Text | Google Scholar

39. Koch BS, Burks RT. Failure of biceps tenodesis with interference screw fixation. Arthroscopy. (2012) 28(5):735–40. doi: 10.1016/j.arthro.2012.02.019

PubMed Abstract | CrossRef Full Text | Google Scholar

40. Müller S, Flury R, Zimmermann S, de Wild M, Fogerty S, Lafosse L, et al. The new LassoLoop360° technique for biomechanically superior tissue grip. Knee Surg Sports Traumatol Arthrosc. (2019) 27(12):3962–9. doi: 10.1007/s00167-019-05604-1

CrossRef Full Text | Google Scholar

41. Guo J, Hou J, Yu M, Alike Y, Long Y, Tang Y, et al. The application of H-loop in arthroscopic knotless double-row rotator cuff repairs. Orthop Surg. (2021) 13(7):2170–6. doi: 10.1111/os.13107

PubMed Abstract | CrossRef Full Text | Google Scholar

42. Burkhart SS, Denard PJ, Konicek J, Hanypsiak BT. Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears. Am J Sports Med. (2014) 42(2):457–62. doi: 10.1177/0363546513516602

PubMed Abstract | CrossRef Full Text | Google Scholar

Keywords: biceps tenodesis, H-loop, all-inside, arthroscopy, functional outcomes

Citation: Zhou M, Zhou C, Cui D, Long Y, Guo J, Zheng Z, Meng K, Zhang J, Hou J and Yang R (2022) The high resistance loop (H-loop) technique used for all-inside arthroscopic knotless suprapectoral biceps tenodesis: A case series. Front. Surg. 9:917853. doi: 10.3389/fsurg.2022.917853

Received: 11 April 2022; Accepted: 26 August 2022;
Published: 14 September 2022.

Edited by:

Paphon Sa-ngasoongsong, Mahidol University, Thailand

Reviewed by:

Nobuyuki Yamamoto, Tohoku University, Japan
Osvaldo Mazza, Bambino Gesù Children’s Hospital (IRCCS), Italy
Yunfei Hou, Peking University People's Hospital, China

© 2022 Zhou, Zhou, Cui, Long, Guo, Zheng, Meng, Zhang, Hou and Yang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Rui Yang yangr@mail.sysu.edu.cn Jingyi Hou houjy7@mail.sysu.edu.cn

These authors have contributed equally to this work.

Specialty Section: This article was submitted to Orthopedic Surgery, a section of the journal Frontiers in Surgery

Abbreviations LHBT, long head of biceps tendon; H-loop, high resistance loop; ASES, American Shoulder and elbow surgeon score; VAS, visual analog scale; SST, simple shoulder test score; UCLA, Los Angeles scoring system; PDS, polydioxanone suture.

Download