1-888-610-7664

sales@GlobalTestSupply.com

Chat Live

Customer Reviews

Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC

Model: RAYGPC

Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC-


Downloads: datasheet manual

Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC

Model: RAYGPC

1/8 DIN digital panel meter provides a compact, easy-to-use interface and display for process instruments that can be used with many Raytek noncontact, infrared temperature sensors.

1/8 DIN digital panel meter provides a compact, easy-to-use interface and display for process instruments that can be used with many Raytek noncontact, infrared temperature sensors.

Sale Price $740.17 USD
Regular Price $827.00 USD
Availability 5 in Stock
Quantity

Raytek RAYGPC Offers

Features

  • Accepts any 0–5 V or 4–20 mA sensor input
  • Accepts type J, K, E, N, R, S, and T thermocouple inputs
  • 5V alarm outputs
  • Compact 1/8 DIN monitor
  • Large 4-digit LED display
  • Universal 110/220 VAC power
  • Provides 24 VDC/50 mA excitation voltage
  • User defined 4–20 mA or thermocouple output (J, K, E, N, R, S, T)
  • Adjustable dual setpoints and deadband controlling alarm outputs
  • Advanced signal processing capabilites including Peak and Valley Hold, Averaging and User adjustable offset
  • External reset input

Raytek RAYGPC Specifications

Resolution 0–5V Input: 1 mV; 4–20 mA Input: 0.01 mA; 4–20 mA Output: 0.014 mA
Accuracy (mV) 0–5V Input: ±2 mV; 4–20 mA Input/Output: ±0.02 mA
Accuracy (t/c) J, K, E, N, T Input/Output: ±0.05% or ±2°C, whichever is greater; R, S Input: ±0.5% or ±3°C, whichever is greater; R, S Output: ±0.5% or ±4°C, whichever is greater;
System Repeatability 500 mSec
Response Time (95%) ± 0.5% of reading or ± 2°C, whichever is greater
Signal Processing Peak Hold, Valley Hold (up to 998 sec, 999=infinite hold with external reset), Variable averaging filter (up to 60 seconds)
Inputs User-configurable, 0–5 V or 4–20 mA or J, K, E, N, R, S, T thermocouple. External reset input to reset Peak/Valley Hold circuit.
Outputs 4-digit, 7-segment LED display; °C/°F selectable; User-configurable 4–20 mA current or thermocouple output (J, K, E, N, R, S, T). Two adjustable setpoints with deadbands controlling 5V alarm outputs; 24VDC/50 mA excitation voltage for powering external sensor
Power Supply 110/220 VAC, ±20%, 50/60 Hz

 

Click here for complete specifications on the Raytek RAYGPC

What's included with the Raytek RAYGPC

  • Digital panel meter
  • Panel mounting hardware

Click on a category to view a selection of compatible accessories with the Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC.

Raytek XXXCB25W High Temperature 7 Conductor Cable for Raytek GPRC Models, 7.7m (25 ft) XXXCB25W
Features a 7-pin DIN connector. For use with coolable housing.








Raytek XXXCB50W High Temperature 7 Conductor Cable for Raytek GPRC Models, 15m (50 ft) XXXCB50W
Features a 7-pin DIN connector. For use with coolable housing.





Raytek XXXGPSSRAC Solid State Relay for 5VDC Alarm Outputs for Raytek GPC Models, 10A/24-330VAC XXXGPSSRAC
A solid state relay is a switching output for setpoint use as a control for an alarm or triggering mechanism. The setpoint output can supply 15mA at 5V for SSR control. Two relays are necessary to take advantage of both setpoints.




Ask a question about Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC

Raytek RAYGPC Offers

Features

  • Accepts any 0–5 V or 4–20 mA sensor input
  • Accepts type J, K, E, N, R, S, and T thermocouple inputs
  • 5V alarm outputs
  • Compact 1/8 DIN monitor
  • Large 4-digit LED display
  • Universal 110/220 VAC power
  • Provides 24 VDC/50 mA excitation voltage
  • User defined 4–20 mA or thermocouple output (J, K, E, N, R, S, T)
  • Adjustable dual setpoints and deadband controlling alarm outputs
  • Advanced signal processing capabilites including Peak and Valley Hold, Averaging and User adjustable offset
  • External reset input

Raytek RAYGPC Specifications

Resolution 0–5V Input: 1 mV; 4–20 mA Input: 0.01 mA; 4–20 mA Output: 0.014 mA
Accuracy (mV) 0–5V Input: ±2 mV; 4–20 mA Input/Output: ±0.02 mA
Accuracy (t/c) J, K, E, N, T Input/Output: ±0.05% or ±2°C, whichever is greater; R, S Input: ±0.5% or ±3°C, whichever is greater; R, S Output: ±0.5% or ±4°C, whichever is greater;
System Repeatability 500 mSec
Response Time (95%) ± 0.5% of reading or ± 2°C, whichever is greater
Signal Processing Peak Hold, Valley Hold (up to 998 sec, 999=infinite hold with external reset), Variable averaging filter (up to 60 seconds)
Inputs User-configurable, 0–5 V or 4–20 mA or J, K, E, N, R, S, T thermocouple. External reset input to reset Peak/Valley Hold circuit.
Outputs 4-digit, 7-segment LED display; °C/°F selectable; User-configurable 4–20 mA current or thermocouple output (J, K, E, N, R, S, T). Two adjustable setpoints with deadbands controlling 5V alarm outputs; 24VDC/50 mA excitation voltage for powering external sensor
Power Supply 110/220 VAC, ±20%, 50/60 Hz

 

Click here for complete specifications on the Raytek RAYGPC

What's included with the Raytek RAYGPC

  • Digital panel meter
  • Panel mounting hardware

Click on a category to view a selection of compatible accessories with the Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC.

Raytek XXXCB25W High Temperature 7 Conductor Cable for Raytek GPRC Models, 7.7m (25 ft) XXXCB25W
Features a 7-pin DIN connector. For use with coolable housing.








Raytek XXXCB50W High Temperature 7 Conductor Cable for Raytek GPRC Models, 15m (50 ft) XXXCB50W
Features a 7-pin DIN connector. For use with coolable housing.





Raytek XXXGPSSRAC Solid State Relay for 5VDC Alarm Outputs for Raytek GPC Models, 10A/24-330VAC XXXGPSSRAC
A solid state relay is a switching output for setpoint use as a control for an alarm or triggering mechanism. The setpoint output can supply 15mA at 5V for SSR control. Two relays are necessary to take advantage of both setpoints.




Ask a question about Raytek RAYGPC Panel Meter with 5VDC Alarm Outputs, 110/220VAC

More Raytek Products