Features
- Measures DO concentration/saturation with Orion polarographic or RDO optical probes
- AUTO-READ function alerts user and locks stable readings on backlit LCD screen
- USB and RS-232 ports allow easy data transfer of up to 5000 time-stamped data points
- Free ground shipping
- Expedited repair and warranty service
- Lifetime technical support
- More
Overview
The Thermo Orion Star A323 portable RDO/DO meter stands up to demanding field applications to deliver advanced readings in any location. Four AA batteries, included with the purchase of the Thermo Orion Star A323, provide over 800 hours of continuous operation. Compatible with Orion polarographic and RDO optical probes, the waterproof, battery-operated meter displays reliable DO concentration, DO saturation and temperature readings on a large, backlit LCD screen that automatically locks in stable readings.
Storage
The Thermo Orion Star A320 series portable meters provide the largest storage capacity available for time-stamped data points, which can be conveniently uploaded to a PC through the meter's USB and RS-232 ports. The Thermo Orion Star A323 supports several calibration methods and compensation options to produce accurate readings, while icons provide quick updates on battery life, electrode status and calibration information. The simple button layout and on-screen messages also assist with calibration and explain setup menu choices.
Benefits
- AUTO-READ function to alert user and lock on-screen readings when stable
- Accepts Orion polarographic and RDO optical probes
- Automatic temperature compensation, manual salinity compensation and automatic or manual barometric pressure compensation
- Calibration options include water-saturated air, air-saturated water, Winkler titration and zero point
- Non-volatile memory holds up to 5000 data points
- Electrode arm and newly-designed probe holder to place probes into samples
- Universal power supply or battery power option
- USB and RS-232 ports to upload data and update included data analysis software
- Multilanguage interface supports English, Spanish, French, Italian, German and Chinese
- IP67-rated housing (may be immersed for up to one hour with no water incursion)
- 3 year meter warranty
- Dissolved Oxygen Polarographic Concentration (% Sat)
- Range: 0 to 90 mg/L (0 to 600 %)
- Resolution: 0.01, 0.1 (0.1,1)
- Relative Accuracy: +/-0.2 (+/-2 %)
- Dissolved Oxygen RDO Concentration (% Sat)
- Range: 0 to 50 mg/L (0 to 500 %)
- Resolution: 0.01, 0.1 (0.1,1)
- Relative Accuracy: +/-0.1 up to 8 mg/L;+/-0.2 from 8 to 20 mg/L; 10% of reading above 20 mg/L(+/-2 %)
- Dissolved Oxygen
- Manual Barometric Pressure Compensation: 450.0 to 850.0 mm Hg
- Manual Salinity Factor Correction: 0 to 45 ppt
- Calibration Features: Water-saturated air, air-saturated water, manual (Winkler) and zero point
- Sensor type: Polarographic or RDO
- Temperature
- Range: 0 to 50 C
- Resolution: 0.1
- Relative Accuracy: +/-0.1 C
- Offset Calibration: 1 point
- Datalogging
- Number of Points: 5000 with time and date stamp
- Log Function: Manual, Automatic with AUTO-READ
- Log Edit: Delete last reading or all
- General
- Display: Backlit LCD
- Inputs: 9-pin mini-DIN
- Output: RS-232, USB
- Power Adapter: Universal AC, 100-240 VAC
- Battery Power: 4 AAs, 800 hrs life
- Environmental Requirements: 5 to 45 C and 5 to 85% relative humidity, non-condensing
- Regulatory and Safety: CE, TUV 3-1, FCC Class A
- IP Rating: IP67, waterproof
- Warranty: 36 months (from date of purchase)
In The News
Choosing The Right Thermo Portable For Your Project
With so many options in Thermo Scientific’s Orion Star A line, it can be difficult to narrow down which meter will best fulfill a project’s needs. One easy way to rule out some meters is by considering application type. For projects that rely largely on collecting samples in the field, a portable meter is clearly the way to go. But there’s still a handful of meters to choose from. 
 
To simplify making the right choice, we spoke with Ricki Hartwell, the global product manager for Thermo Scientific’s Orion Laboratory and Field Instruments. She recently shared her tips on choosing the right Thermo benchtop. Let’s take a look at her recommendations for selecting the right portable meter.
Read MoreApplied Research and Innovative Solutions: Creating CHNGES at Western Kentucky University
Long-standing environmental monitoring programs have the power to support a large number of research initiatives and policy changes—however, actually starting these networks can prove challenging. Not only is starting the program difficult, but keeping things operational for decades to come has also been challenging for environmental professionals hoping to make an impact with applied research. 
 
Jason Polk, Professor of Environmental Geoscience and Director of the Center for Human GeoEnvironmental Studies (CHNGES) at Western Kentucky University, is all too familiar with this process.
Read MoreCombating Water Insecurity in Saskatchewan with Real-Time Data
The prairies of Saskatchewan can be described as one of the least water-secure parts of Canada, making water quality monitoring essential for informed resource management in a region already facing water insecurity. While natural physical properties worsen some of the poor water quality conditions in the region, others are connected to land use. 
 
Having grown up spending summers on the shores of Lake Huron, Helen Baulch, an associate professor at the School of Environment and Sustainability at the University of Saskatchewan , has always been dedicated to the protection of water resources. 
 
Looking back fondly at her childhood playing along the shore, Baulch also recalls the invasion of quagga mussels during her teenage years and watching the lake change as a result.
Read More